合肥肥西园区消防维保问题整改项目结果公示
招标公告 合肥肥西园区消防维保问题整改项目结果公示
更新时间 2024-08-02
关键词
广东省  
还不是会员?马上来注册查看所有信息 查看更多
{"**":{"******":"合肥肥西园区消防维保问题整改项目","****":"************/**","**********":"*","**********":"*","******************":****,"****************":****,"******************":*************,"****************":*************,"****************":*************,"****************":****,"***************":*************,"*****************":*************,"***************":****,"*****************":****,"***********":****,"**********":*,"**********":*,"**************":"合肥市肥西县华*路与国际大道深国际肥西综合物流港*#综合楼行政中心","******":*************,"********":**,"********":"合肥市肥西县华*路与国际大道深国际肥西综合物流港*#综合楼行政中心","*********":*,"***********":*************,"*********":*************,"****************":"自合同签订之日起**天","********":"*.电气火灾监控主机无电:需要更换电源;*.防火门监控主机打印机故障:需要更换打印机;*.停车场下水泵房控制柜手动状态下会自动启动水泵接不能手动关停:建议根据厂家提供的控制柜设计图纸重新连接控制线路并调试;*.综合楼*-**层报警阀组测试时警铃及压力开关不动作:建议更换管路上的球阀及过滤器;*.*#综合楼楼顶稳压泵气压罐压力为*:建议联系更换气压罐或隔膜;*.*期报警主机提示**个故障:建议对*#、*#库故障区域的***电源线路及电源块更换;*.*期测试的部分区域报警阀组启动测试报警管路动作时间过长及不动作:建议加设节流孔板或更换待遇节流孔板的延时器;*.*期*#库北*/*分区之间防火卷帘无法动作:建议重新布置*相电源线至库区强电配电箱;*.*期配电房气体灭火系统现场测试探测器无动作:建议根据原设计图纸完善该系统未完成工作。","***********":"*.投标人必须是在中华人民共和国境内注册(不含港、澳、台地区)的独立法人机构或能够独立承担民事责任的其他组织(不含分支机构/分公司)。提供营业执照复印件或组织机构代码证等或其他市场主体开办证明;*.自招标公告发布之日起,投标人未被列入“信用中国”网站(***.***********.***.**)以下任意记录名单之*:①失信被执行人;②重大税收违法案件当事人名单,以及未处于“行政处罚”的处罚禁止期限内;*.本项目不接受联合体投标;*.其他资质要求。","*****************":*****,"**************":"*","****************":*,"*******":*,"***********":*,"***************************":****,"***********************":****,"***************":*,"*************":*******.**,"**************":"*","****************":"*","******************":"*","****************":"*","****************":*,"***********":****,"*******************":*,"*******":**,"**************":"","**************":*,"*************":****,"**************":*,"******************":*,"****************":*,"********":*,"*********":*,"************":****,"**************":****,"**************":*,"****************":*,"****************":****,"**************":****,"***************":****},"***********":[],"********":{"****":"********-****-****-****-************","*********":*,"*****":"合肥肥西园区消防维保问题整改项目结果公示","***********":*************,"****************":*************,"**************":*************,"******":"合肥肥西园区消防维保问题整改项目","**************":****,"********":****,"***":****,"*****************":"*","********************":[{"*******":"合肥尧安消防工程有限公司","*****":****,"************":"*****.**","**********":****,"********":****,"*******":****,"***********":****,"**********":****,"***********":****,"************":****,"**********":****,"*********":****,"********":****,"******************":****,"******":****}],"*****************":****,"*******":****,"************":****,"********":[{"*******":"合肥尧安消防工程有限公司","************":"*****.**"}],"**************************":****},"**":{"******":"合肥肥西园区消防维保问题整改项目","****":"************","*********":*,"*********":*,"******":"交通运输、仓储和邮政业","*******":"合肥市肥西县华*路与国际大道交口东南角深国际肥西综合物流港","******":"*.电气火灾监控主机无电:需要更换电源;*.防火门监控主机打印机故障:需要更换打印机;*.停车场下水泵房控制柜手动状态下会自动启动水泵接不能手动关停:建议根据厂家提供的控制柜设计图纸重新连接控制线路并调试;*.综合楼*-**层报警阀组测试时警铃及压力开关不动作:建议更换管路上的球阀及过滤器;*.*#综合楼楼顶稳压泵气压罐压力为*:建议联系更换气压罐或隔膜;*.*期报警主机提示**个故障:建议对*#、*#库故障区域的***电源线路及电源块更换;*.*期测试的部分区域报警阀组启动测试报警管路动作时间过长及不动作:建议加设节流孔板或更换待遇节流孔板的延时器;*.*期*#库北*/*分区之间防火卷帘无法动作:建议重新布置*相电源线至库区强电配电箱;*.*期配电房气体灭火系统现场测试探测器无动作:建议根据原设计图纸完善该系统未完成工作。","************":*,"***************":****,"*********":*,"*************":*,"**************":*,"**************":*,"*******":"合肥深鹏综合物流港发展有限公司","*************":"张翠","**************":"****-********","**********":"安徽省合肥市肥西县经济开发区 华*路与国际大道交口合肥乾龙现代物流园内*#综合楼","********":****,"***************":****,"******************":****,"*******************":****,"******************":****,"***********":****,"*****************":****,"**********":****,"**************":****}}
收藏

热门推荐

项目推荐

比比招标网 > 中标公告> 合肥肥西园区消防维保问题整改项目结果公示

Title

客服电话 400-000-0388

手机版 ——  电脑版 ——  APP版 ——  微信版 ——  关于我们

版权所有©2018 比比网络 bibenet.com